Switchboard WiresBare Copper WiresBuilding WiresInstrumentation Cables600V Multi-Conductor Control Tray Cables600V Multi-Condutor Power Cables and VFD Cables600V Interlocked Armored Instrumentation Cables600V Interlocked Armor Control Cables600V-35kV Interlocked Armor Power CablesFlexible Portable CordsFlexing Portable Mining CablesMV-105 Power CablesIN STOCK Belden and Belden Equals or Similar         
 
 
 
                                     
All Categories > Building Wires  
 

Building Wires


Click on a Product to view details.

Type XHHW-2 Building Wires

Type XHHW-2 Building Wires 600V

(19)

APPLICATIONS:
General purpose building wire for use in air, cable tray or approved raceways, industrial environments where superior insulation toughness and chemical resistance are required, and where maximum operating temperature not to exceed 90°C in dry or wet locations. Wire possesses excellent electrical, thermal and physical properties, excellent resistance to moisture, and excellent resistance to crush, compression cuts and heat deformation.
 
CONSTRUCTION:
Stranded tinned or bare copper conductor, black XLP (Cross-Linked Polyethylene) insulation, surface printed.
 
STANDARDS:
*    Conductors ...

Type Use-2 or RHW-2 or RHH Building Wires

Type Use-2 or RHW-2 or RHH Building Wires 600V

(19)

APPLICATIONS:
Where NEC jurisdiction applies; as Type USE-2 for direct burial, 90 deg.C. in wet locations; and as Type RHW-2, 90 deg.C. in wet locations, or Type RHH, 90 deg.C. in dry locations, installed in air, conduit, or other recognized raceway. Sizes 1/0 and larger may be installed in cable tray per Article 318 of NEC. Otherwise, for general purpose applications at maximum conductor temperature of 90 deg.C. locations – including conduit, duct, tray trough, direct burial, and aerial installations.
 
CONSTRUCTION:
Stranded tinned or bare copper conductor, black XLP insulation, surface printed.
 
STANDARDS: ...

Type RHW-2 Building Wires

Type USE-2 or RHW-2 or RHH Building Wires 2kV

(17)

APPLICATIONS:
Where NEC jurisdiction applies; as Type RHW-2, 90 deg.C. in wet or dry locations, installed in air, conduit, or other recognized raceway. Sizes 1/0 and larger may be installed in cable tray per Article 318 of NEC. Otherwise, for general purpose applications at maximum conductor temperature of 90 deg.C. locations – including conduit, duct, tray trough, direct burial, and aerial installations.
 
CONSTRUCTION:
Stranded tinned or bare copper conductor, black XLP insulation, surface printed.
 
STANDARDS:
*   Conductors conform to ASTM B-3 & B-8 (& B-33 for tinned copper conductor). ...

Type Use-2 or RHW-2 or RHH Building Wires

Type PV or RHW-2 or RHH Building Wires 600V

(20)

APPLICATIONS:
Single conductor, sunlight resistant, direct burial, photovoltaic wire rated 90°C wet or dry,600V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electric Code (NEC),NFPA 70.
 
CONSTRUCTION:
Stranded bare copper conductor, black XLP insulation, surface printed.
 
STANDARDS:
*   Conductors conform to ASTM B-3 & B-8
* RHW-2 (90°C wet/dry) or RHH (90°C dry)per UL
*   PV Type (90°C wet/dry) per UL4703.
* Cables (1/0AWG and larger)designed to pass ...

Type RHW-2 Building Wires

Type PV or RHW-2 or RHH Building Wires 2kV

(20)

APPLICATIONS:
Single conductor, sunlight resistant, direct burial, photovoltaic wire rated 90°C wet or dry,600V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electric Code (NEC),NFPA 70.

CONSTRUCTION:
Stranded bare copper conductor, black XLP insulation, surface printed.

STANDARDS:
* Conductors conform to ASTM B-3 & B-8
* RHW-2 (90°C wet/dry) or RHH (90°C dry)per UL
* PV Type (90°C wet/dry) per UL4703.
* Cables (1/0AWG and larger)designed to pass the IEEE-383, IEEE-1202/CSA FT-4 ...

Site created by ThomasNet Web Solutions
Basic Wire and Cable Company