Switchboard WiresBare Copper WiresBuilding WiresInstrumentation Cables600V Multi-Conductor Control Tray Cables600V Multi-Condutor Power Cables and VFD Cables600V Interlocked Armored Instrumentation Cables600V Interlocked Armor Control Cables600V-35kV Interlocked Armor Power CablesFlexible Portable CordsFlexing Portable Mining CablesMV-105 Power CablesIN STOCK Belden and Belden Equals or Similar         
 
 
 
                                     
All Categories > 600V-35kV Interlocked Armor Power Cables  
 

600V-35kV Interlocked Armor Power Cables


Click on a Product to view details.

Search Items
MC-IAC Power

Type MC-IAC Interlocked Armor Power Cables 600 Volts

(32)

APPLICATIONS:
Where NEC jurisdiction applies; as Type MC cable, 90 deg.C. in wet or dry locations; for installation aerially, in conduit, cable trays, in underground ducts, with messenger or direct buried, for power and control circuits not exceeding 600 volts in manufacturing and processing plants, substations and generating stations. When installed per the NEC, cables meet requirements of OSHA. Permitted for use in Class I, Class II, Division 2, Class III Division 1 and 2 hazardous locations per the NEC. Suitable for direct burial.
 
CONSTRUCTION:
Three-, or four conductors of stranded copper, XLP (Cross-Linked Polyethylene) insulated, phase-identified, conductors ...

Search  Type MC-IAC Interlocked Armor Power Cables 600 Volts - 32 Items

type mcaic armored non shield

Type MC-IAC Interlocked Armor Power Cables Non Shielded 2.4kV

(12)

APPLICATIONS:
Where NEC jurisdiction applies; as Type MV-105 cable for installation aerially in conduits or in underground ducts, direct buried, or isolated in air, dry or wet locations, in cable trays, or with messenger, for power and control circuits not exceeding 2400 volts in manufacturing and processing plants, substations and generating stations. When installed per NEC, cables meet the requirements of OSHA. Otherwise, for general-purpose applications where the protection of interlocked armor is required.
 
CONSTRUCTION:
Three conductors of stranded copper, extruded semi-conducting layer, 115-mil EPR (Ethylene Propylene Rubber) insulation, phase ...

Search  Type MC-IAC Interlocked Armor Power Cables Non Shielded 2.4kV - 12 Items

5kV Type MCiac

Type MC-IAC Interlocked Armor Power Cables Shielded 5kV/8kV

(13)

APPLICATIONS:
Where NEC jurisdiction applies; as Type MV-105 cable for installation aerially in conduits or in underground ducts, direct buried, or isolated in air, dry or wet locations, in cable trays, or with messenger, for power and control circuits not exceeding 5,000 volts at 133% insulation level for 105 deg.C. continuous, 140 deg.C. emergency, and 250 deg.C. short-circuit operation, in manufacturing and processing plants, substations and generating stations. When installed per NEC, cables meet the requirements of OSHA. Otherwise, for general-purpose applications where the protection of interlocked armor is required.
 
CONSTRUCTION:
Stranded copper ...

Search  Type MC-IAC Interlocked Armor Power Cables Shielded 5kV/8kV - 13 Items

Type MC-IAC 15kv

Type MC-IAC Interlocked Armor Power Cables Shielded 15kV

(11)
APPLICATIONS:
Where NEC jurisdiction applies; as Type MV-105 cable for installation aerially in conduits or in underground ducts, direct buried, or isolated in air, dry or wet locations, in cable trays, or with messenger, for power and control circuits not exceeding 15,000 volts at 133% insulation level for 105 deg.C. continuous, 140 deg.C. emergency, and 250 deg.C. short-circuit operation, in manufacturing and processing plants, substations and generating stations. When installed per NEC, cables meet the requirements of OSHA. Otherwise, for general-purpose applications where the protection of interlocked armor is required.
 
CONSTRUCTION:
Stranded copper conductors, ...

Search  Type MC-IAC Interlocked Armor Power Cables Shielded 15kV - 11 Items

type mc 25-35kV

Type MC-IAC Interlocked Armor Power Cables Shielded 25-35kV

(7)
APPLICATIONS:
Where NEC jurisdiction applies; as Type MV-105 cable for installation aerially or in metal rack, tray, trough or cable trays, for power and control circuits not exceeding 25,000/35,000 volts at 133% and 100% insulation levels for 105 deg.C. continuous, 140 deg.C. emergency, and 250 deg.C. short-circuit operation in manufacturing and processing plants, substations and generating stations. When installed per NEC, cables meet the requirements of OSHA.
 
CONSTRUCTION:
Stranded copper conductors, semi-conducting layer, EPR insulation, semi-conducting layer, helically applied copper tape shield, conductors phase identified. Three conductors cabled together with a ...

Search  Type MC-IAC Interlocked Armor Power Cables Shielded 25-35kV - 7 Items

Teck 3 conductor power with groun d

TECK-90 Type Interlocked Armor Power Cables 600 Volts

(13)

APPLICATIONS:
Suitable for exposed and concealed wiring in dry, damp or wet locations, for use in ventilated, non-ventilated and ladder-type cable trays in dry, damp or wet locations, for direct earth burial, also for wiring in all hazardous locations when used with certified HL cable fittings.
 
CONSTRUCTION:
Stranded copper conductors, XLP (Cross-Linked Polyethylene) insulated, Method 1 - Table E1 or E2 color-coded or Method 4 phase-identified conductors cabled with suitable fillers as necessary, inner PVC (Polyvinyl Chloride) jacket, aluminum interlocked armor, black PVC jacket overall, surface printed.
 
STANDARDS: ...

Search  TECK-90 Type Interlocked Armor Power Cables 600 Volts - 13 Items

VFD/TECK-90 Armored

TYPE VFD/TECK-90 Interlocked Armor Power Cables

(18)

APPLICATIONS:
Teck-90 cable is suitable for use in exposed or concealed wiring at temperatures of 90°C in dry or wet locations, in ventilated or ladder type cable trays in dry or wet conditions, on walls or beams, or directly buried, for power and control circuits not exceeding 600 volts in manufacturing and processing plants, substations and generating stations. Suitable for use in NEC Hazardous locations: Class I, Div. 2 and Class II, Div. 2. Suitable for variable frequency drive applications.

CONSTRUCTION:
Stranded copper conductors, XLP (Cross-Linked Polyethylene) insulated, Method 4 phase-identified; three insulated conductors cabled together with one stranded ...

Search  TYPE VFD/TECK-90 Interlocked Armor Power Cables - 18 Items