Call Us Today: (800) 227-4292 | E-mail: basicwire@basicwire.com
  GO
Switchboard WiresBare Copper WiresBuilding WiresInstrumentation Cables600V Multi-Conductor Control Tray Cables600V Multi-Condutor Power Cables and VFD Cables600V Interlocked Armored Instrumentation Cables600V Interlocked Armor Control Cables600V-35kV Interlocked Armor Power CablesFlexible Portable CordsFlexing Portable Mining CablesMV-105 Power CablesIN STOCK Belden and Belden Equals or Similar         
 
 
 
                                     
All Categories > MV-105 Power Cables  
 

MV-105 Power Cables


Click on a Product to view details.

Type EPR single

Type EPR Power Cables 5kV/8kV-1C

(14)

APPLICATION:
A-    Where NEC jurisdiction applies; as 5000/8000 volts shielded power cable (133/100% insulation levels), Type MV-105, for use at conductor temperature not exceeding 105 deg.C. in wet or dry locations, when installed in accordance with the National Electrical Code.
B-  Otherwise, for general purpose applications in wet or dry locations, in circuits not exceeding 5000 volts, phase to phase, at conductor temperatures not exceeding 105 deg.C. for normal, 130 deg.C. for emergency overload, and 250 deg.C. circuit conditions. Suitable for installation in conduit, trays, troughs, ducts, aerial, and direct burial applications.
 
CONSTRUCTION: ...

Search  Type EPR Power Cables 5kV/8kV-1C - 14 Items

EPR 3 conductor

Type EPR Power Cables 5kV/8kV-3C

(14)

APPLICATION:
A- Where NEC jurisdiction applies; as 5000 volts shielded power cable, Type MV-105, for use at conductor temperature not exceeding 105 deg.C. in wet or dry locations, when installed in accordance with the National Electrical Code.
B- Otherwise, for general purpose applications in wet or dry locations, in circuits not exceeding 5000 volts, phase to phase, at conductor temperatures not exceeding 105 deg.C. for normal, 130 deg.C. for emergency overload, and 250 deg.C.circuit conditions. Suitable for installation in conduit, trays, troughs, ducts, aerial, and direct burial applications.

CONSTRUCTION:
Stranded copper conductor, semi-conducting layer, EPR insulation, semi-conducting layer, ...

Search  Type EPR Power Cables 5kV/8kV-3C - 14 Items

Type EPR single

Type EPR Power Cables 15kV-1C

(11)

APPLICATION:
A-    Where NEC jurisdiction applies; as 15000 volts shielded power cable, Type MV-105, for use at conductor temperature not exceeding 105 deg.C. in wet or dry locations, when installed in accordance with the National Electrical Code.
B-  Otherwise, for general purpose applications in wet or dry locations, in circuits not exceeding 15000 volts, phase to phase, at conductor temperatures not exceeding 105 deg.C. for normal, 130 deg.C. for emergency overload, and 250 deg.C.circuit conditions. Suitable for installation in conduit, trays, troughs, ducts, aerial, and direct burial applications.
 
CONSTRUCTION: 
Stranded copper conductor, ...

Search  Type EPR Power Cables 15kV-1C - 11 Items

EPR 3 conductor

Type EPR Power Cables 15kV-3C

(10)
APPLICATION:
A-    Where NEC jurisdiction applies; as 15000 volts shielded power cable, Type MV-105, for use at conductor temperature not exceeding 105 deg.C. in wet or dry locations, when installed in accordance with the National Electrical Code.
B-  Otherwise, for general purpose applications in wet or dry locations, in circuits not exceeding 15000 volts, phase to phase, at conductor temperatures not exceeding 105 deg.C. for normal, 130 deg.C. for emergency overload, and 250 deg.C.circuit conditions. Suitable for installation in conduit, trays, troughs, ducts, aerial, and direct burial applications.
 
CONSTRUCTION:
Stranded copper conductor, ...

Search  Type EPR Power Cables 15kV-3C - 10 Items

Site created by ThomasNet Web Solutions
Basic Wire and Cable Company