Call Us Today: (800) 227-4292 | E-mail: basicwire@basicwire.com
  GO
Switchboard WiresBare Copper WiresBuilding WiresInstrumentation Cables600V Multi-Conductor Control Tray Cables600V Multi-Condutor Power Cables and VFD Cables600V Interlocked Armored Instrumentation Cables600V Interlocked Armor Control Cables600V-35kV Interlocked Armor Power CablesFlexible Portable CordsFlexing Portable Mining CablesMV-105 Power CablesIN STOCK Belden and Belden Equals or Similar         
 
 
 
                                     
All Categories > 600V Multi-Conductor Power Cables and VFD Cables  
 

600V Multi-Conductor Power Cables and VFD Cables


Click on a Product to view details.

Search Items
tc-g pvc

Type TC-G XLP/PVC Power Cables

(34)


APPLICATIONS:
As three- or four-conductor power cables rated 600 volts, 90 deg. C. in dry or wet locations. Specifically approved for installation in cable trays per Article 340 of the NEC. Type TC cables are permitted for use in Class I Division 2 industrial hazardous locations per NEC. Cables may be installed in free air, raceways or direct burial, in wet or dry locations. All cables when used in accordance with the NEC, meet the requirements of OSHA.
 
CONSTRUCTION:
Stranded copper conductors, XLP (Cross-Linked Polyethylene) insulated, Method 1 - Table E1 or E2 color-coded, or Method 4 phase-identified. Insulated conductors ...

Search  Type TC-G XLP/PVC Power Cables - 34 Items

tc-g cpe

Type TC-G XLP/CPE Power Cables

(34)


APPLICATIONS:
As three- or four-conductor power cables rated 600 volts, 90 deg. C. in dry or wet locations. Specifically approved for installation in cable trays per Article 340 of the NEC. Type TC cables are permitted for use in Class I Division 2 industrial hazardous locations per NEC. Cables may be installed in free air, raceways or direct burial, in wet or dry locations. All cables when used in accordance with the NEC, meet the requirements of OSHA.
 
CONSTRUCTION:
Stranded copper conductors, XLP (Cross-Linked Polyethylene) insulated, Method 1 - Table E1 or E2 color-coded, or Method 4 phase-identified. Insulated conductors cabled with a stranded copper ...

Search  Type TC-G XLP/CPE Power Cables - 34 Items

Type TC Power Cable LSZH

Type TC-G XLP/LSZH Power Cables

(34)


APPLICATIONS:
As three- or four-conductor power cables rated 600 volts, 90 deg. C. in dry or wet locations. Specifically approved for installation in cable trays per Article 340 of the NEC. Type TC cables are permitted for use in Class I Division 2 industrial hazardous locations per NEC. Cables may be installed in free air, raceways or direct burial, in wet or dry locations. All cables when used in accordance with the NEC, meet the requirements of OSHA.
 
CONSTRUCTION:
Stranded copper conductors, XLP (Cross-Linked Polyethylene) insulated, Method 1 - Table E1 or E2 color-coded, or Method 4 phase-identified. Insulated conductors cabled with a stranded copper ...

Search  Type TC-G XLP/LSZH Power Cables - 34 Items

VFD 3d

Type VFD Power Cables

(42)


APPLICATIONS:
Shielded power cables for important circuits in industrial plants and station control cable for electric utilities in fossil fueled or nuclear generating stations. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600 volts; recommended for operation at 90°C continuous conductor temperature in dry or wet locations; approved for installation in cable trays per Article 336 of the NEC, and for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Suitable for variable frequency drive applications. ...

Search  Type VFD Power Cables - 42 Items

Site created by ThomasNet Web Solutions
Basic Wire and Cable Company