Switchboard WiresBare Copper WiresBuilding WiresInstrumentation Cables600V Multi-Conductor Control Tray Cables600V Multi-Condutor Power Cables and VFD Cables600V Interlocked Armored Instrumentation Cables600V Interlocked Armor Control Cables600V-35kV Interlocked Armor Power CablesFlexible Portable CordsFlexing Portable Mining CablesMV-105 Power CablesIN STOCK Belden and Belden Equals or Similar         
 
 
 
                                     
All Categories > 600V-35kV Interlocked Armor Power Cables > Type MC-IAC Interlocked Armor Power Cables Non Shielded 2.4kV > View Items  

Type MC-IAC Interlocked Armor Power Cables Non Shielded 2.4kV

Check up to five results to perform an action.

APPLICATIONS:
Where NEC jurisdiction applies; as Type MV-105 cable for installation aerially in conduits or in underground ducts, direct buried, or isolated in air, dry or wet locations, in cable trays, or with messenger, for power and control circuits not exceeding 2400 volts in manufacturing and processing plants, substations and generating stations. When installed per NEC, cables meet the requirements of OSHA. Otherwise, for general-purpose applications where the protection of interlocked armor is required.
 
CONSTRUCTION:
Three conductors of stranded copper, extruded semi-conducting layer, 115-mil EPR (Ethylene Propylene Rubber) insulation, phase identification. Three conductors twisted together with a stranded copper grounding conductor in one interstice, suitable fillers, binder tape, aluminum interlocked armor, yellow PVC (Polyvinyl Chloride) jacket overall, surface printed.
 
STANDARDS:
*    Conforms to MV-105 and MC specs per UL 1072.
*    Overall jacket suitable for Sunlight Resistant and Direct Burial applications.
*    Cables designed to pass the IEEE-383 ribbon burner flame test and are suitable “For CT Use.”
*    Cables meet the requirements of ICEA S-96-659.

                

 



Search Items



    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

 DOWNLOADS 

Type MC-IAC 2.4kV 3-c NONSHIELDED SPEC. SHEET
(PDF, 138KB)

Compare Items
   
  Results 1 - 12 of 12 1 

Part #

Conductor Size

No. of Conductors

O.D. Over PVC JKT. (in)

Weight (lbs/mft)

Conductor Color Coding Methods

9-3006-G 4 AWG 3 1.43 1115 N/A
9-3007-G 2 AWG 3 1.54 1430 N/A
9-3008-G 1 AWG 3 1.61 1770 N/A
9-3009-G 1/0 AWG 3 1.72 2025 N/A
9-3010-G 2/0 AWG 3 1.85 2390 N/A
9-3011-G 3/0 AWG 3 1.96 3000 N/A
9-3012-G 4/0 AWG 3 2.08 3395 N/A
9-3013-G 250 MCM 3 2.20 3900 N/A
9-3015-G 350 MCM 3 2.46 5105 N/A
9-3017-G 500 MCM 3 2.73 6800 N/A
9-3019-G 750 MCM 3 3.14 9400 N/A
9-3020-G 1000 MCM 3 3.43 12050 N/A