Switchboard WiresBare Copper WiresBuilding WiresInstrumentation Cables600V Multi-Conductor Control Tray Cables600V Multi-Condutor Power Cables and VFD Cables600V Interlocked Armored Instrumentation Cables600V Interlocked Armor Control Cables600V-35kV Interlocked Armor Power CablesFlexible Portable CordsFlexing Portable Mining CablesMV-105 Power CablesIN STOCK Belden and Belden Equals or Similar         
 
 
 
                                     
All Categories > 600V-35kV Interlocked Armor Power Cables > Type MC-IAC Interlocked Armor Power Cables Shielded 5kV/8kV > View Items  

Type MC-IAC Interlocked Armor Power Cables Shielded 5kV/8kV

Check up to five results to perform an action.

APPLICATIONS:
Where NEC jurisdiction applies; as Type MV-105 cable for installation aerially in conduits or in underground ducts, direct buried, or isolated in air, dry or wet locations, in cable trays, or with messenger, for power and control circuits not exceeding 5,000 volts at 133% insulation level for 105 deg.C. continuous, 140 deg.C. emergency, and 250 deg.C. short-circuit operation, in manufacturing and processing plants, substations and generating stations. When installed per NEC, cables meet the requirements of OSHA. Otherwise, for general-purpose applications where the protection of interlocked armor is required.
 
CONSTRUCTION:
Stranded copper conductors, semi-conducting layer, EPR insulation, semi-conducting layer, helically applied copper tape shield, conductors phase identified. Three conductors cabled together with a stranded copper grounding conductor in one interstice, suitable fillers, binder tape, aluminum or galvanized steel interlocked armor, yellow PVC jacket overall, surface printed.
 
STANDARDS:
*   Conforms to AEIC CS8.
*   Type MV-105 MC cable per article 334 of the NEC.
*   Overall jacket suitable for Sunlight Resistant and Direct Buried applications.
*   Cables designed to pass the IEEE-383 ribbon burner flame test and are suitable “For CT Use.”
*   Cables conform to ICEA S-93-639 and ICEA S-97-682.

 
 

 

 



Search Items



    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

 DOWNLOADS 

Type MC-IAC Shielded 5kV/8kV SPEC. SHEET
(PDF, 153KB)

Compare Items
   
  Results 1 - 13 of 13 1 

Part #

Conductor Size

No. of Conductors

O.D. Over PVC JKT. (in)

Alum Weight (lbs/mft)

Galv. Steel Weight (lbs/mft)

Conductor Color Coding Methods

9-3054-G 8 AWG 3 1.31 770 lbs/m 990 lbs/m N/A
9-3055-G 6 AWG 3 1.47 985 lbs/m 1205 lbs/m N/A
9-3056-G 4 AWG 3 1.58 1360 lbs/m 1745 lbs/m N/A
9-3057-G 2 AWG 3 1.71 1775 lbs/m 2160 lbs/m N/A
9-3058-G 1 AWG 3 1.78 2055 lbs/m 2475 lbs/m N/A
9-3059-G 1/0 AWG 3 1.91 2335 lbs/m 2745 lbs/m N/A
9-3060-G 2/0 AWG 3 2.01 2705 lbs/m 3130 lbs/m N/A
9-3061-G 3/0 AWG 3 2.12 2920 lbs/m 3375 lbs/m N/A
9-3062-G 4/0 AWG 3 2.24 3730 lbs/m 4290 lbs/m N/A
9-3063-G 250 MCM 3 2.36 4200 lbs/m 4770 lbs/m N/A
9-3067-G 500 MCM 3 2.93 7490 lbs/m 8210 lbs/m N/A
9-3069-G 750 MCM 3 3.37 10385 lbs/m 11195 lbs/m N/A
9-3070-G 1000 MCM 3 3.69 13345 lbs/m 14150 lbs/m N/A