Call Us Today: (800) 227-4292 | E-mail: basicwire@basicwire.com
  GO
Switchboard WiresBare Copper WiresBuilding WiresInstrumentation Cables600V Multi-Conductor Control Tray Cables600V Multi-Condutor Power Cables and VFD Cables600V Interlocked Armored Instrumentation Cables600V Interlocked Armor Control Cables600V-35kV Interlocked Armor Power CablesFlexible Portable CordsFlexing Portable Mining CablesMV-105 Power CablesIN STOCK Belden and Belden Equals or Similar         
 
 
 
                                     
All Categories > 600V Interlocked Armor Control Cables > TECK-90 Type Interlocked Armor Control Cables 600 Volts > View Items  

TECK-90 Type Interlocked Armor Control Cables 600 Volts

Check up to five results to perform an action.

APPLICATIONS:
Suitable for exposed and concealed wiring in dry, damp or wet locations, for use in ventilated, non-ventilated and ladder-type cable trays in dry, damp or wet locations, for direct earth burial, also for wiring in all hazardous locations when used with certified HL cable fittings.
 
CONSTRUCTION:
Stranded copper conductors, XLP (Cross-Linked Polyethylene) insulated, Method 1 - Table E1 or E2 color-coded or Method 4 phase-identified conductors cabled with suitable fillers as necessary, inner PVC (Polyvinyl Chloride) jacket, aluminum interlocked armor, black PVC jacket overall, surface printed.
 
STANDARDS:
*   Conductors conform to ASTM B3 & B 8.
*   Insulation conforms to UL Standard 44, and is approved as Type XHHW-2.
*   TECK-90/HL Type per CSA Std. C22.2.
*   Overall jacket approved as Sunlight Resistant and “For CT Use.”
*   Cables designed to pass the IEEE-383 and IEEE-1202 tests. *
*   Cables meet requirements of ICEA S-95-658/NEMA WC70. 
 



Search Items



    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

 DOWNLOADS 

Conductor Color Coding Methods
(PDF, 319KB)

TECK-90 TYPE SPEC. SHEET
(PDF, 140KB)

Compare Items
   
  Results 1 - 36 of 36 1 

Part #

Conductor Size

No. of Conductors

O.D. Over PVC JKT. (in)

Weight (lbs/mft)

9-102-TK 14 AWG 2 0.67 195
9-103-TK 14 AWG 3 0.69 226
9-104-TK 14 AWG 4 0.72 256
9-105-TK 14 AWG 5 0.76 290
9-107-TK 14 AWG 7 0.82 338
9-109-TK 14 AWG 9 0.93 420
9-112-TK 14 AWG 12 0.99 511
9-115-TK 14 AWG 15 1.04 586
9-119-TK 14 AWG 19 1.12 732
9-125-TK 14 AWG 25 1.30 958
9-131-TK 14 AWG 31 1.38 1110
9-137-TK 14 AWG 37 1.44 1320
9-202-TK 12 AWG 2 0.70 228
9-203-TK 12 AWG 3 0.73 254
9-204-TK 12 AWG 4 0.77 293
9-205-TK 12 AWG 5 0.81 350
9-207-TK 12 AWG 7 0.91 443
9-209-TK 12 AWG 9 0.99 624
9-212-TK 12 AWG 12 1.10 653
9-215-TK 12 AWG 15 1.16 757
9-219-TK 12 AWG 19 1.25 890
9-225-TK 12 AWG 25 1.42 1210
9-231-TK 12 AWG 31 1.51 1375
9-237-TK 12 AWG 37 1.59 1580
9-302-TK 10 AWG 2 0.75 275
9-303-TK 10 AWG 3 0.78 327
9-304-TK 10 AWG 4 0.83 413
9-305-TK 10 AWG 5 0.91 473
9-307-TK 10 AWG 7 0.99 552
9-309-TK 10 AWG 9 1.09 720
9-312-TK 10 AWG 12 1.23 916
9-315-TK 10 AWG 15 1.30 1084
9-319-TK 10 AWG 19 1.39 1255
9-325-TK 10 AWG 25 1.55 1612
9-331-TK 10 AWG 31 1.68 1880
9-337-TK 10 AWG 37 1.77 2075
  Results 1 - 36 of 36 1 
Site created by ThomasNet Web Solutions
Basic Wire and Cable Company